The most of luminaires manufacturers are requested to do IK level test (Impact Protection). LISUN can supply the IK test instrument.
IK ratings are defined as IKXX, where "XX" is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
Degrees of protection against external mechanical impacts:
IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J |
The IK07-10 is applied for IK07, IK08, IK09 and IK10 test.